View and Configure AppSocket Settings

Function Description
Appsocket Enabled (Phaser 360 printer)

Port Enabled (Phaser 380, 350, 340, 560, 550, 600 printers)

This field allows you to enable and disable the protocol.

Language

Select the language you want the printer to receive on the AppSocket port; the choices are listed here (not all printers support all languages):

Host Access List

This field allows you to give access to the selected printer only to certain hosts. No entry indicates that all hosts have access to the selected printer. To give a host exclusive access to the printer, enter the host's IP address in the field. With the Phaser 360 printer, you can enter up to 10 valid IP addresses by separating the addresses with a single space; for other printers, you can enter up to six addresses.

Receive Window Size*

This field allows you to change the default AppSocket Receive Window Size. The value entered must either be 0 or a number between 1024 and 59392. If 0 is entered, the printer uses the window size desired by the print host. If a number between 1024 and 59392 is entered, the window size depends on a negotiation between the printer and the host computer.

Send Window Size*

This field allows you to change the default AppSocket Send Window Size. The value entered must either be 0 or a number between 1024 and 59392. If 0 is entered, the printer uses the window size desired by the print host. If a number between 1024 and 59392 is entered, the window size depends on a negotiation between the printer and the host computer.

Filtering

This field allows you to choose whether the printer strips out control characters. The choices are InterpreterBased or None. In most cases, Filtering should be set to None.

Delayed Output Close*

When you choose True (On), the printer does not begin a new job on this port until the current job is completed. When you choose False (Off), the printer can begin processing a new job while it is still printing a previous job.

For Phaser 380, 350, 340, 560, 550, 600 printers: If Delayed Output Close is False (Off), job accounting is disabled for the AppSocket protocol.

* If these fields are not displayed, they are not supported by the printer.