Operating range: temperature and humidity
The operating range is contained within the temperature/humidity space defined by the following points:
Celsius:
15.5 deg. C / 10% RH
32.2 deg. C / 10% RH
32.2 deg. C / 60% RH
25.5 deg. C / 80% RH
15.5 deg. C / 80% RH
Fahrenheit:
60 deg. F / 10% RH
90 deg. F / 10% RH
90 deg. F / 60% RH
78 deg. F / 80% RH
60 deg. F / 80% RH
The best print quality is obtained within these limits:
15.5 deg. to 25.5 deg. C (60 deg. to 78 deg. F), and 20% to 65% relative humidity
Temperature
Non-operating: 0 deg. C to 40 deg. C (32 deg. F to 104 deg. F)
Storage: (without paper, transparencies, or consumables): -20 deg. C to +60 deg. C
(-4 deg. F to +140 deg. F)
Humidity
Non-operating: 10% to 90% relative humidity, non-condensing
Altitude
Operating: 0 to 2,500 m (8,000 ft.).
Non-operating: 0 to 4000 m (13,125 ft.)
Primary voltage ranges
90 - 132 VAC, 110 VAC nominal
198 - 264 VAC, 220 VAC nominal
Frequency range
50 to 60 Hz
Primary fusing
125 VAC, 10 Amps and 8 Amps
250 VAC, 5 Amps and 4 Amps
(Not user-accessible)
Power Consumption
Meets Energy Star power conservation requirements.
State
|
Average power
|
Continuous printing
|
380 W
|
Idle
|
115 W
|
Energy Star
|
45 W or under
|
Dimensions of standard unit
(without Lower Tray Assembly)
Height: 464 mm (18.3 in.)
Depth: 501 mm (19.7 in.)
Width: 507 mm (20* in.)
*782 mm (30.8 in.) with the output tray
Dimensions of Lower Tray Assembly
Height: 249 mm (9.8 in.)
Depth: 405 mm (16.0 in.)
Width: 447 mm (17.6 in.)
Return to Topic List
|