Skip to main contentClick to view our Accessibility Statement or contact us with accessibility-related questions.

Phaser 540


Cleaning the corona wire
When your prints show vertical light streaks that are wavy and appear in all colors, the corona wire needs to be cleaned. If cleaning doesn't take care of the problem, the corona wire may be worn out and need to be replaced. Separate replacement of the corona wire should not be required often, since each new imaging unit includes a new corona wire already installed, and the average life of these two components is similar.

  1. Turn the power off.

  2. Open the front door.

  3. Pinch the handle of the corona wire to remove it.

  4. Remove the cleaning tool from inside the printer.

  5. Insert the cleaning tool on the underside of the corona wire housing, as shown.

  6. Wipe the corona wire with a back and forth motion.

  7. Replace the cleaning tool inside the printer.

  8. Replace the corona wire in the printer.

  9. Close the front door and turn the power on.

Reset the copy count

If you replace the corona wire, reset its copy count by completing these steps.

  1. Press the Menu button to enter the front panel menu. You will see this message in the display:

    Help Pages
    <--- ---> Menu

  2. Press the right arrow button (--->) until the display reads

    System Counts
    <--- ---> Menu

  3. Press the Menu button to enter the System Counts menu.

  4. Press the right arrow button (--->) until the display reads

    Corona Wire
    <--- ---> Menu

  5. Press the Menu button; then press the Reset button.

  6. Press the Exit button until the display reads Ready.


Support Home Page
Phaser 540 Support Page

Network Printers Support Home
Additional Information

Register your Printer
ASPs & TPMs
About Software Support
Color Connection
Printer Warranties
Material Safety Data Sheets
Supplies & Cartridge Recycling Program